Backflow Prevention

A backflow preventer is the one plumbing device that protects everyone else: it stops contaminated water, whether from irrigation lines, boilers, fire systems or commercial equipment, from flowing backward into the drinking water supply when pressure conditions reverse.

Because the stakes are public health, backflow assemblies live in a world of rules: many jurisdictions require annual testing by certified testers, failed tests trigger repair deadlines, and installations must match the hazard level. This section covers testing, repair, installation and replacement of backflow assemblies.

Our Services

Signs You Need This Service

Signs a backflow assembly needs attention:

  • Relief valve discharging. An RPZ relieving water, dripping or flushing, is doing its job while telling you a check or the relief valve itself needs service.
  • Failed annual test. A failed test report is a service order: checks, springs or seats inside the assembly are not holding.
  • Continuous or intermittent dripping. Fouled or worn internals; debris from line work is a classic trigger.
  • Low flow or pressure downstream. A clogged or failing assembly throttles everything behind it.
  • Noisy, chattering assembly. Checks slamming under fluctuating demand; wear accelerates from here.
  • Freeze damage. Outdoor and above-grade assemblies crack in freezes; a split housing is a replacement, not a repair.

Sounds like your problem? Request a quote →

Common Causes

What actually goes wrong inside:

  • Worn check valves and springs. Rubber and spring internals age on a known schedule, the reason annual testing exists.
  • Debris fouling. Grit after utility work or line repairs lodges in the checks and holds them open.
  • Pressure events. Backsiphonage (supply-side pressure loss) and backpressure (downstream pressure rise) are the two conditions assemblies exist to survive, and the events that reveal weak internals.
  • Freezing. Water trapped in the body expands and cracks housings and relief valves.
  • Wrong device for the hazard. A device rated below the hazard level (or installed in the wrong orientation or height) fails inspection regardless of its condition.

Service Details & What's Included

The work this section covers:

  • Annual testing. Certified testing of RPZ, double-check and PVB assemblies with documented results filed where the jurisdiction requires them.
  • Repair. Rebuild kits (checks, springs, seats, relief valve internals) restore most assemblies; a retest confirms the fix.
  • Replacement. Cracked housings, obsolete models without parts, or repeated failures end in replacement matched to the hazard level and local approval lists.
  • Installation. New assemblies for irrigation, fire lines, commercial equipment and multi-unit buildings: correct device class, orientation, clearances and drainage for relief discharge.

Frequently Asked Questions

What is the difference between backsiphonage and backpressure?

Backsiphonage is suction: pressure in the supply drops, from a main break or hydrant use, and water gets pulled backward. Backpressure is push: a downstream system such as a boiler or pump exceeds supply pressure and forces water back. Assemblies are rated for one or both.

Why is my backflow preventer leaking from the relief valve?

An RPZ discharges by design when a check fails to hold or the relief valve itself is fouled. Occasional spitting during pressure swings can be normal; steady discharge means the assembly needs service and a retest.

What happens if a backflow test fails?

The failed report typically starts a repair clock with the water authority. The assembly is rebuilt or replaced, then retested, and passing results are filed. Ignoring the deadline can end in water service action.

Can an RPZ or double-check be repaired, or must it be replaced?

Most assemblies are built to be rebuilt; manufacturers sell complete internals kits. Replacement wins when the housing is cracked, parts are discontinued, or failures repeat after rebuilds.

Does every property need annual backflow testing?

It is jurisdiction-specific: most water authorities require annual tests for commercial assemblies, irrigation connections and fire lines; some extend requirements to residential devices. Your water provider's cross-connection program is the authority.

Who is allowed to test a backflow preventer?

Testers certified under the programs your jurisdiction recognizes, using calibrated gauges, with results filed on the authority's forms. Verify certification when scheduling; it is a legitimate question, not an insult.

Schedule Backflow Service

Have the assembly's type and location handy, and the notice, if a test or the water authority triggered the visit. That defines the job before anyone arrives.

Request a Quote for Backflow Preventionor call (800) 555-0147

Only license-checked plumbers who cover your ZIP receive your request.